天天摸天天碰天天添中文字幕,国产区点击进入在线影院,无码人妻一区二区免费AV,亚洲精品国产av现线

產(chǎn)品中心

人鋅指蛋白746(ZNF746)酶聯(lián)免疫吸附檢測(cè)試劑盒
ELK8990
規(guī)格: 價(jià)格:
48T ¥1960.00
96T ¥2800.00

Overview 文獻(xiàn)

Product name: Human ZNF746(Zinc finger protein 746) ELISA Kit
Reactivity: Human
Alternative Names: FLJ31413; zinc finger protein 746; ZNF746
Assay Type: Sandwich
Sensitivity: 6.5 pg/mL
Standard: 1000 pg/mL
Detection Range: 15.63-1000 pg/mL
Sample Type: Serum, plasma, tissue homogenates and other biological fluids.
Assay Length: 3.5h
Research Area: Neuro science
Uniprot ID: Q6NUN9
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human ZNF746. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human ZNF746. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human ZNF746, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human ZNF746 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線(xiàn)

Concentration (pg/mL) OD Corrected OD
1000.00 2.258 2.172
500.00 1.699 1.613
250.00 1.147 1.061
125.00 0.834 0.748
62.50 0.597 0.511
31.25 0.372 0.286
15.63 0.216 0.130
0.00 0.086 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant ZNF746 and the recovery rates were calculated by comparing the measured value to the expected amount of ZNF746 in samples.
Matrix Recovery range Average
serum(n=5) 86-99% 92%
EDTA plasma(n=5) 86-99% 92%
Heparin plasma(n=5) 79-93% 86%

線(xiàn)性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of ZNF746 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 85-97% 87-96% 82-95% 92-105%
EDTA plasma(n=5) 90-99% 95-106% 87-101% 85-97%
Heparin plasma(n=5) 87-96% 82-95% 92-105% 78-102%
關(guān)閉

在線(xiàn)咨詢(xún)

Online consultation

  • 在線(xiàn)咨詢(xún)
  • 技術(shù)支持

關(guān)注微信公眾號(hào)

微信掃一掃立即咨詢(xún)

微信掃一掃立即咨詢(xún)

關(guān)閉
石棉县| 肇州县| 额敏县| 湖南省| 花莲县| 平潭县| 双流县| 安新县| 汉川市| 屯门区| 潜山县| 莱芜市| 虞城县| 潮安县| 安龙县| 拉萨市| 富宁县| 南充市| 施秉县| 黄冈市| 宁夏| 晋州市| 周口市| 凤山市| 疏勒县| 南投市| 轮台县| 阿合奇县| 黄陵县| 郧西县| 吉林市| 香格里拉县| 安阳市| 富宁县| 怀远县| 岗巴县| 光山县| 中西区| 禹城市| 阿克陶县| 札达县|