天天摸天天碰天天添中文字幕,国产区点击进入在线影院,无码人妻一区二区免费AV,亚洲精品国产av现线

產(chǎn)品中心

人基質(zhì)金屬蛋白酶12(MMP12)酶聯(lián)免疫吸附檢測試劑盒
ELK2355
規(guī)格: 價格:
48T ¥1960.00
96T ¥2800.00

Overview 文獻(xiàn)

Product name: Human MMP12(Matrix Metalloproteinase 12) ELISA Kit
Reactivity: Human
Alternative Names: MME; HME; ME; Macrophage Metalloelastase; Macrophage Elastase
Assay Type: Sandwich
Sensitivity: 0.12 ng/mL
Standard: 20 ng/mL
Detection Range: 0.32-20 ng/mL
Sample Type: Serum, plasma and other biological fluids
Assay Length: 3.5h
Research Area: Enzyme & Kinase;Tumor immunity;Infection immunity;
Uniprot ID: P39900
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human MMP12. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human MMP12. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human MMP12, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human MMP12 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (ng/mL) OD Corrected OD
20.00 1.990 1.886
10.00 1.506 1.402
5.00 1.073 0.969
2.50 0.839 0.735
1.25 0.523 0.419
0.63 0.312 0.208
0.32 0.249 0.145
0.00 0.104 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant MMP12 and the recovery rates were calculated by comparing the measured value to the expected amount of MMP12 in samples.
Matrix Recovery range Average
serum(n=5) 89-107% 98%
EDTA plasma(n=5) 87-99% 93%
Heparin plasma(n=5) 78-90% 84%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of MMP12 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 86-93% 91-103% 87-98% 95-101%
EDTA plasma(n=5) 89-99% 83-95% 98-104% 96-106%
Heparin plasma(n=5) 85-100% 84-98% 95-101% 88-102%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
大宁县| 天水市| 江安县| 长沙县| 彰武县| 扶风县| 泉州市| 武强县| 玛纳斯县| 巫山县| 铁岭县| 兴宁市| 定襄县| 信宜市| 河西区| 九江市| 新疆| 高台县| 延津县| 米脂县| 淳安县| 临颍县| 赤城县| 崇明县| 通城县| 稻城县| 台东县| 五寨县| 滁州市| 西充县| 山阳县| 台湾省| 沙河市| 大名县| 政和县| 卢氏县| 应城市| 沅陵县| 平果县| 韶关市| 衡阳县|