天天摸天天碰天天添中文字幕,国产区点击进入在线影院,无码人妻一区二区免费AV,亚洲精品国产av现线

產(chǎn)品中心

大鼠內(nèi)皮型一氧化氮合酶(NOS3)酶聯(lián)免疫吸附檢測(cè)試劑盒
ELK1501
規(guī)格: 價(jià)格:
48T ¥1960.00
96T ¥2800.00

Overview 文獻(xiàn)

Product name: Rat NOS3(Nitric Oxide Synthase 3, Endothelial) ELISA Kit
Reactivity: Rat
Alternative Names: ECNOS; NOS III; E-NOS; C-NOS; ENOS; CNOS; Constitutive NOS
Assay Type: Sandwich
Sensitivity: 0.62 ng/mL
Standard: 100 ng/mL
Detection Range: 1.57-100 ng/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates and other biological fluids
Assay Length: 3.5h
Research Area: Enzyme & Kinase;Cardiovascular biology;
Uniprot ID: Q62600
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Rat NOS3. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Rat NOS3. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Rat NOS3, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Rat NOS3 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (ng/mL) OD Corrected OD
100.00 1.809 1.707
50.00 1.558 1.456
25.00 1.183 1.081
12.50 0.827 0.725
6.25 0.406 0.304
3.13 0.377 0.275
1.57 0.216 0.114
0.00 0.102 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant NOS3 and the recovery rates were calculated by comparing the measured value to the expected amount of NOS3 in samples.
Matrix Recovery range Average
serum(n=5) 83-97% 90%
EDTA plasma(n=5) 86-99% 92%
Heparin plasma(n=5) 80-92% 86%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of NOS3 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 93-102% 81-96% 93-106% 82-95%
EDTA plasma(n=5) 88-103% 86-97% 87-102% 89-101%
Heparin plasma(n=5) 87-98% 92-101% 82-98% 89-97%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號(hào)

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
吉隆县| 武乡县| 大化| 阳高县| 河南省| 江安县| 都昌县| 师宗县| 保康县| 新蔡县| 宁海县| 西丰县| 高阳县| 孟连| 屯昌县| 上栗县| 星子县| 林芝县| 遂昌县| 永登县| 梓潼县| 襄垣县| 双牌县| 孟村| 平舆县| 天祝| 界首市| 大丰市| 克拉玛依市| 临邑县| 万山特区| 安达市| 青河县| 苏尼特左旗| 长顺县| 班玛县| 浦东新区| 石狮市| 赤水市| 页游| 周宁县|