天天摸天天碰天天添中文字幕,国产区点击进入在线影院,无码人妻一区二区免费AV,亚洲精品国产av现线

產(chǎn)品中心

人干擾素γ誘導(dǎo)單核因子(MIg)酶聯(lián)免疫吸附檢測試劑盒
ELK1284
規(guī)格: 價格:
48T ¥1680.00
96T ¥2400.00

Overview 文獻

Product name: Human MIg(Monokine Induced By Interferon Gamma) ELISA Kit
Reactivity: Human
Alternative Names: CXCL9; CMK; Humig; MI-G; SCYB9; Crg-10; Chemokine (C-X-C motif) ligand 9; Small-inducible cytokine B9; Gamma-interferon-induced monokine
Assay Type: Sandwich
Sensitivity: 12.8 pg/mL
Standard: 2000 pg/mL
Detection Range: 31.25-2000 pg/mL
Sample Type: Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Cytokine;Infection immunity;
Uniprot ID: Q07325
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human MIg. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human MIg. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human MIg, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human MIg in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (pg/mL) OD Corrected OD
2000.00 2.258 2.163
1000.00 1.653 1.558
500.00 1.108 1.013
250.00 0.671 0.576
125.00 0.515 0.420
62.50 0.379 0.284
31.25 0.213 0.118
0.00 0.095 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant MIg and the recovery rates were calculated by comparing the measured value to the expected amount of MIg in samples.
Matrix Recovery range Average
serum(n=5) 86-99% 92%
EDTA plasma(n=5) 80-92% 86%
Heparin plasma(n=5) 83-97% 90%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of MIg and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 78-95% 96-103% 83-101% 82-97%
EDTA plasma(n=5) 85-94% 97-103% 79-91% 82-91%
Heparin plasma(n=5) 95-102% 83-96% 97-103% 85-92%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
灌云县| 汝阳县| 新平| 西贡区| 内江市| 巨鹿县| 洞口县| 安图县| 平利县| 邵阳市| 东港市| 南充市| 牡丹江市| 大厂| 新野县| 板桥市| 滕州市| 古浪县| 淮北市| 剑川县| 鄂托克前旗| 云南省| 桦甸市| 广州市| 台中市| 莱州市| 靖州| 开化县| 丰顺县| 迭部县| 宁城县| 巨野县| 简阳市| 麦盖提县| 崇仁县| 沙坪坝区| 社会| 鄂尔多斯市| 宝山区| 新闻| 利津县|