天天摸天天碰天天添中文字幕,国产区点击进入在线影院,无码人妻一区二区免费AV,亚洲精品国产av现线

產(chǎn)品中心

人巨噬細胞炎性蛋白3α(MIP3a)酶聯(lián)免疫吸附檢測試劑盒
ELK1119
規(guī)格: 價格:
48T ¥1680.00
96T ¥2400.00

Overview

Product name: Human MIP3a(Macrophage Inflammatory Protein 3 Alpha) ELISA Kit
Reactivity: Human
Alternative Names: MIP3 Alpha; CCL20; CKb4; LARC; MIP3-A; SCYA20; ST38; Small Inducible Cytokine Subfamily A(Cys-Cys)Member 20; Beta-Chemokine Exodus-1; Liver And Activation-Regulated Chemokine
Assay Type: Sandwich
Sensitivity: 2.9 pg/mL
Standard: 500 pg/mL
Detection Range: 7.82-500 pg/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Cytokine;Infection immunity;
Uniprot ID: P78556
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human MIP3a. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human MIP3a. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human MIP3a, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human MIP3a in the samples is then determined by comparing the OD of the samples to the standard curve.

標準曲線

Concentration (pg/mL) OD Corrected OD
500.00 2.266 2.184
250.00 1.527 1.445
125.00 1.088 1.006
62.50 0.892 0.810
31.25 0.539 0.457
15.63 0.318 0.236
7.82 0.186 0.104
0.00 0.082 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant MIP3a and the recovery rates were calculated by comparing the measured value to the expected amount of MIP3a in samples.
Matrix Recovery range Average
serum(n=5) 78-96% 87%
EDTA plasma(n=5) 78-92% 85%
Heparin plasma(n=5) 80-95% 87%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of MIP3a and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 88-100% 95-103% 89-97% 85-94%
EDTA plasma(n=5) 87-103% 97-105% 79-90% 87-96%
Heparin plasma(n=5) 93-99% 87-101% 85-95% 85-96%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
鄱阳县| 桦甸市| 思南县| 黔江区| 连城县| 文化| 石景山区| 麦盖提县| 广东省| 杭州市| 岐山县| 武汉市| 迁西县| 通江县| 辉南县| 夏河县| 灌云县| 宝兴县| 巴彦淖尔市| 礼泉县| 抚松县| 布拖县| 历史| 嵊泗县| 蒲江县| 房产| 淮北市| 博白县| 伊吾县| 白城市| 商河县| 东方市| 尼勒克县| 泉州市| 新田县| 惠水县| 昭苏县| 霍林郭勒市| 潍坊市| 金川县| 湄潭县|