天天摸天天碰天天添中文字幕,国产区点击进入在线影院,无码人妻一区二区免费AV,亚洲精品国产av现线

產品中心

人葡萄糖激酶(GCK)酶聯免疫吸附檢測試劑盒
ELK1111
規(guī)格: 價格:
48T ¥1680.00
96T ¥2400.00

Overview

Product name: Human GCK(Glucokinase) ELISA Kit
Reactivity: Human
Alternative Names: GK; GLK; HHF3; HK4; HKIV; HXKP; MODY2; Hexokinase-D; Hexokinase 4; Maturity Onset Diabetes Of The Young 2
Assay Type: Sandwich
Sensitivity: 0.23 ng/mL
Standard: 50 ng/mL
Detection Range: 0.79-50 ng/mL
Sample Type: Tissue homogenates and other biological fluids.
Assay Length: 3.5h
Research Area: Enzyme & Kinase;Metabolic pathway;Endocrinology;Nutrition metabolism;
Uniprot ID: P35557
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human GCK. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human GCK. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human GCK, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human GCK in the samples is then determined by comparing the OD of the samples to the standard curve.

標準曲線

Concentration (ng/mL) OD Corrected OD
50.00 2.388 2.235
25.00 1.649 1.496
12.50 1.240 1.087
6.25 0.797 0.644
3.13 0.474 0.321
1.57 0.302 0.149
0.79 0.287 0.134
0.00 0.153 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant GCK and the recovery rates were calculated by comparing the measured value to the expected amount of GCK in samples.
Matrix Recovery range Average
serum(n=5) 80-97% 88%
EDTA plasma(n=5) 83-95% 89%
Heparin plasma(n=5) 90-105% 97%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of GCK and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 85-98% 88-104% 86-102% 79-93%
EDTA plasma(n=5) 89-97% 85-94% 87-101% 85-96%
Heparin plasma(n=5) 85-94% 87-101% 82-95% 82-93%
關閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術支持

關注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關閉
泰来县| 嘉定区| 忻城县| 抚远县| 尼勒克县| 金阳县| 杭州市| 嘉义县| 建瓯市| 惠东县| 环江| 洞头县| 扶余县| 沾化县| 阳东县| 崇阳县| 绵阳市| 永平县| 陕西省| 宁强县| 阜康市| 祁连县| 马公市| 庆云县| 长垣县| 黔东| 西宁市| 庆云县| 板桥市| 聂拉木县| 左贡县| 龙里县| 宁乡县| 日照市| 洛南县| 丰县| 卢湾区| 库车县| 江油市| 桓仁| 枞阳县|