天天摸天天碰天天添中文字幕,国产区点击进入在线影院,无码人妻一区二区免费AV,亚洲精品国产av现线

產(chǎn)品中心

人激肽釋放酶10(KLK10)酶聯(lián)免疫吸附檢測試劑盒
ELK1110
規(guī)格: 價格:
48T ¥1680.00
96T ¥2400.00

Overview

Product name: Human KLK10(Kallikrein 10) ELISA Kit
Reactivity: Human
Alternative Names: NES1; PRSSL1; Kallikrein-Related Peptidase 10; Normal epithelial cell-specific 1; Protease serine-like 1
Assay Type: Competitive Inhibition
Sensitivity: 48.8 pg/mL
Standard: 10000 pg/mL
Detection Range: 156.25-10000 pg/mL
Sample Type: Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 2h
Research Area: Enzyme & Kinase;Tumor immunity;Reproductive science;
Uniprot ID: O43240
Test principle: This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with Human KLK10. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human KLK10. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human KLK10 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (pg/mL) OD Corrected OD
10000.00 0.199
5000.00 0.385
2500.00 0.596
1250.00 0.878
625.00 1.169
312.50 1.537
156.25 1.715
0.00 2.213

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant KLK10 and the recovery rates were calculated by comparing the measured value to the expected amount of KLK10 in samples.
Matrix Recovery range Average
serum(n=5) 85-95% 90%
EDTA plasma(n=5) 79-93% 86%
Heparin plasma(n=5) 95-107% 101%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of KLK10 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 87-102% 85-94% 87-101% 89-99%
EDTA plasma(n=5) 85-101% 78-96% 79-98% 93-102%
Heparin plasma(n=5) 92-101% 82-98% 89-97% 85-93%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
紫金县| 财经| 朝阳县| 兴山县| 平果县| 上饶县| 抚州市| 兰考县| 海城市| 南汇区| 丰县| 台南市| 渭源县| 确山县| 西乌珠穆沁旗| 晋城| 吐鲁番市| 旬阳县| 泰宁县| 阿拉善盟| 布拖县| 依安县| 昭觉县| 成安县| 江川县| 大连市| 防城港市| 宁城县| 汉寿县| 西宁市| 浦东新区| 合江县| 怀集县| 裕民县| 朔州市| 淮滨县| 大竹县| 琼中| 仪征市| 武平县| 隆德县|