天天摸天天碰天天添中文字幕,国产区点击进入在线影院,无码人妻一区二区免费AV,亚洲精品国产av现线

產(chǎn)品中心

人S100鈣結(jié)合蛋白A12(S100A12)酶聯(lián)免疫吸附檢測試劑盒
ELK1073
規(guī)格: 價格:
48T ¥1680.00
96T ¥2400.00

Overview

Product name: Human S100A12(S100 Calcium Binding Protein A12) ELISA Kit
Reactivity: Human
Alternative Names: CGRP; P6; CAAF1; CAGC; ENRAGE; MRP6; Calgranulin C; Calcium-binding protein in amniotic fluid 1; Extracellular newly identified RAGE-binding; Migration inhibitory factor-related 6
Assay Type: Sandwich
Sensitivity: 31 pg/mL
Standard: 5000 pg/mL
Detection Range: 78.13-5000 pg/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Signal transduction;Infection immunity;Immune molecule;
Uniprot ID: P80511
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human S100A12. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human S100A12. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human S100A12, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human S100A12 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (pg/mL) OD Corrected OD
5000.00 2.103 1.985
2500.00 1.755 1.637
1250.00 1.223 1.105
625.00 0.847 0.729
312.50 0.525 0.407
156.25 0.303 0.185
78.13 0.248 0.130
0.00 0.118 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant S100A12 and the recovery rates were calculated by comparing the measured value to the expected amount of S100A12 in samples.
Matrix Recovery range Average
serum(n=5) 82-95% 88%
EDTA plasma(n=5) 89-103% 96%
Heparin plasma(n=5) 78-93% 85%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of S100A12 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 85-92% 83-96% 78-98% 90-99%
EDTA plasma(n=5) 95-103% 79-92% 97-105% 89-97%
Heparin plasma(n=5) 85-94% 97-106% 82-95% 93-105%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
兴业县| 宝坻区| 克东县| 衢州市| 青冈县| 天镇县| 桃园县| 石阡县| 南澳县| 明溪县| 侯马市| 高台县| 屏山县| 安福县| 玛纳斯县| 武功县| 南川市| 亳州市| 娱乐| 长沙市| 秭归县| 闵行区| 蓝田县| 青阳县| 府谷县| 桐城市| 周至县| 宝清县| 兴文县| 视频| 南昌市| 绥江县| 商都县| 临澧县| 甘泉县| 崇礼县| 莆田市| 河源市| 宜川县| 南投县| 东丰县|