天天摸天天碰天天添中文字幕,国产区点击进入在线影院,无码人妻一区二区免费AV,亚洲精品国产av现线

產(chǎn)品中心

人降鈣素基因相關(guān)肽2(CGRP2)酶聯(lián)免疫吸附檢測(cè)試劑盒
ELK1037
規(guī)格: 價(jià)格:
48T ¥1680.00
96T ¥2400.00

Overview 文獻(xiàn)

Product name: Human CGRP2(Calcitonin Gene Related Peptide 2) ELISA Kit
Reactivity: Human
Alternative Names: CALCB; CGRP2; CALC2; CGRP-II; Calcitonin Gene Related Peptide 2; Calcitonin 2; Calcitonin Related Polypeptide Beta
Assay Type: Sandwich
Sensitivity: 5.19 pg/mL
Standard: 1000 pg/mL
Detection Range: 15.63-1000 pg/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Infection immunity;Endocrinology;Neuro science;Hormone metabolism;Bone metabolism;Dermatology;
Uniprot ID: P06881
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human CGRP. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human CGRP. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human CGRP, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human CGRP in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (pg/mL) OD Corrected OD
1000.00 2.379 2.312
500.00 2.109 2.042
250.00 1.567 1.500
125.00 0.989 0.922
62.50 0.611 0.544
31.25 0.361 0.294
15.63 0.225 0.158
0.00 0.067 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant CGRP and the recovery rates were calculated by comparing the measured value to the expected amount of CGRP in samples.
Matrix Recovery range Average
serum(n=5) 82-95% 88%
EDTA plasma(n=5) 84-96% 90%
Heparin plasma(n=5) 87-101% 94%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of CGRP and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 83-97% 92-103% 87-98% 93-101%
EDTA plasma(n=5) 83-96% 86-95% 90-102% 87-98%
Heparin plasma(n=5) 87-95% 85-96% 92-102% 81-92%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號(hào)

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
图木舒克市| 新津县| 辽宁省| 蒙自县| 遵义市| 吉隆县| 青海省| 三亚市| 郯城县| 青田县| 大厂| 拉萨市| 桃江县| 呼和浩特市| 尉犁县| 濮阳市| 天镇县| 临湘市| 承德市| 德阳市| 正蓝旗| 祁阳县| 家居| 吉安县| 中西区| 界首市| 楚雄市| 乐亭县| 京山县| 班戈县| 和顺县| 东平县| 白河县| 高淳县| 宜黄县| 广宁县| 台中市| 长治县| 伊春市| 商水县| 信宜市|