天天摸天天碰天天添中文字幕,国产区点击进入在线影院,无码人妻一区二区免费AV,亚洲精品国产av现线

產(chǎn)品中心

一步法人組織金屬蛋白酶抑制因子1(TIMP1)酶聯(lián)免疫吸附檢測(cè)試劑盒
ELK086ES
規(guī)格: 價(jià)格:
64T ¥1960.00
112T ¥2800.00

Overview

Product name: EasyStep Human TIMP1(Tissue Inhibitors Of Metalloproteinase 1) ELISA Kit
Reactivity: Human
Alternative Names: EPO; CLGI; EPA; HCI; Erythroid Potentiating Activity; Collagenase Inhibitor; Metalloproteinase inhibitor 1; Fibroblast collagenase inhibitor
Assay Type: Sandwich
Sensitivity: 43.53 pg/mL
Standard: 5000 pg/mL
Detection Range: 78.13-5000 pg/mL
Sample Type: Serum, plasma
Assay Length: 1.5h
Research Area: Tumor immunity;Infection immunity;Cardiovascular biology;Hepatology;Hormone metabolism;
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human TIMP1, and the Human TIMP1 standard plate wells that pre-coated using protein-related techniques are provided separately. Standard/Sample Diluent Buffer or samples are added to the appropriate microtiter plate wells ,then added a HRP-conjugated antibody specific to Human TIMP1. After TMB substrate solution is added, only those wells that contain Human TIMP1 and HRP-conjugated antibody will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human TIMP1 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (pg/mL) OD Corrected OD
5000.00 2.345 2.249
2500.00 1.761 1.665
1250.00 1.183 1.087
625.00 0.647 0.551
312.50 0.521 0.425
156.25 0.393 0.297
78.13 0.258 0.162
0.00 0.096 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant TIMP1 and the recovery rates were calculated by comparing the measured value to the expected amount of TIMP1 in samples.
Matrix Recovery range Average
serum(n=5) 78-90% 84%
EDTA plasma(n=5) 84-97% 91%
Heparin plasma(n=5) 89-105% 97%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of TIMP1 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 89-102% 92-101% 88-102% 87-102%
EDTA plasma(n=5) 88-97% 96-105% 81-96% 93-107%
Heparin plasma(n=5) 85-94% 87-96% 92-101% 82-95%

產(chǎn)品成分表

關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號(hào)

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
榆中县| 腾冲县| 丽水市| 平果县| 蒙阴县| 临颍县| 讷河市| 凉山| 兴海县| 平远县| 庄河市| 双柏县| 仙游县| 历史| 中山市| 平原县| 凉山| 信丰县| 唐山市| 韶山市| 昌江| 高安市| 东乡族自治县| 姚安县| 孝义市| 邵阳市| 佛坪县| 文水县| 临邑县| 新津县| 临江市| 台山市| 边坝县| 涞水县| 北安市| 垫江县| 稷山县| 潜江市| 三江| 安平县| 亳州市|