天天摸天天碰天天添中文字幕,国产区点击进入在线影院,无码人妻一区二区免费AV,亚洲精品国产av现线

產(chǎn)品中心

一步法人超敏C反應(yīng)蛋白(Hs-CRP)酶聯(lián)免疫吸附檢測(cè)試劑盒
ELK037ES
規(guī)格: 價(jià)格:
64T ¥1960.00
112T ¥2800.00

Overview

Product name: EasyStep Human hs-CRP(high sensitivity C Reactive Protein) ELISA Kit
Reactivity: Human
Alternative Names: C-RP; PTX1; Pentraxin-Related; Pentraxin 1
Assay Type: Sandwich
Sensitivity: 21 pg/mL
Standard: 5000 pg/mL
Detection Range: 78.13-5000 pg/mL
Sample Type: Serum, plasma
Assay Length: 1.5h
Research Area: Tumor immunity;Infection immunity;Cardiovascular biology;Rheumatology;
Uniprot ID: P02741
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human CRP, and the Human CRP standard plate wells that pre-coated using protein-related techniques are provided separately. Standard/Sample Diluent Buffer or samples are added to the appropriate microtiter plate wells ,then added a HRP-conjugated antibody specific to Human CRP. After TMB substrate solution is added, only those wells that contain Human CRP and HRP-conjugated antibody will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human CRP in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (pg/mL) OD Corrected OD
5000.00 2.185 2.096
2500.00 1.527 1.438
1250.00 1.111 1.022
625.00 0.813 0.724
312.50 0.591 0.502
156.25 0.239 0.150
78.13 0.187 0.098
0.00 0.089 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant CRP and the recovery rates were calculated by comparing the measured value to the expected amount of CRP in samples.
Matrix Recovery range Average
serum(n=5) 87-99% 93%
EDTA plasma(n=5) 81-95% 88%
Heparin plasma(n=5) 80-95% 87%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of CRP and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 89-97% 93-102% 81-96% 93-106%
EDTA plasma(n=5) 85-94% 92-101% 87-96% 82-90%
Heparin plasma(n=5) 96-105% 88-96% 87-98% 93-101%

產(chǎn)品成分表

關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號(hào)

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
广平县| 固原市| 都兰县| 葵青区| 奇台县| 理塘县| 邵东县| 鄂尔多斯市| 孝感市| 东台市| 刚察县| 察雅县| 荥阳市| 太和县| 石家庄市| 霍城县| 福贡县| 溆浦县| 永泰县| 喀什市| 平远县| 集贤县| 西和县| 沙洋县| 尚志市| 丹巴县| 建平县| 柳江县| 磴口县| 太康县| 金塔县| 河南省| 望谟县| 阿尔山市| 丹棱县| 尉犁县| 讷河市| 绥宁县| 罗平县| 中西区| 清苑县|