天天摸天天碰天天添中文字幕,国产区点击进入在线影院,无码人妻一区二区免费AV,亚洲精品国产av现线

產(chǎn)品中心

一步法人血管內(nèi)皮生長(zhǎng)因子A(VEGFA)酶聯(lián)免疫吸附檢測(cè)試劑盒
ELK033ES
規(guī)格: 價(jià)格:
64T ¥1960.00
112T ¥2800.00

Overview

Product name: EasyStep Human VEGFA(Vascular Endothelial Growth Factor A) ELISA Kit
Reactivity: Human
Alternative Names: VEGF; VEGF-A; VPF; Vascular Endothelial Cell Growth Factor A; Vascular Permeability Factor
Assay Type: Sandwich
Sensitivity: 31 pg/mL
Standard: 5000 pg/mL
Detection Range: 78.2-5000 pg/mL
Sample Type: Serum, plasma
Assay Length: 1.5h
Research Area: Cytokine;Apoptosis;Tumor immunity;
Uniprot ID: P15692
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human VEGFA, and the Human VEGFA standard plate wells that pre-coated using protein-related techniques are provided separately. Standard/Sample Diluent Buffer or samples are added to the appropriate microtiter plate wells ,then added a HRP-conjugated antibody specific to Human VEGFA. After TMB substrate solution is added, only those wells that contain Human VEGFA and HRP-conjugated antibody will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human VEGFA in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (pg/mL) OD Corrected OD
5000.00 2.266 2.183
2500.00 1.674 1.591
1250.00 1.243 1.160
625.00 0.845 0.762
312.50 0.585 0.502
156.25 0.293 0.210
78.13 0.179 0.096
0.00 0.083 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant VEGFA and the recovery rates were calculated by comparing the measured value to the expected amount of VEGFA in samples.
Matrix Recovery range Average
serum(n=5) 80-95% 87%
EDTA plasma(n=5) 80-95% 87%
Heparin plasma(n=5) 86-99% 92%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of VEGFA and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 98-105% 92-101% 85-105% 87-98%
EDTA plasma(n=5) 88-104% 84-98% 95-105% 88-102%
Heparin plasma(n=5) 88-95% 98-107% 90-99% 88-97%

產(chǎn)品成分表

關(guān)閉

在線咨詢(xún)

Online consultation

  • 在線咨詢(xún)
  • 技術(shù)支持

關(guān)注微信公眾號(hào)

微信掃一掃立即咨詢(xún)

微信掃一掃立即咨詢(xún)

關(guān)閉
南城县| 五台县| 宁安市| 噶尔县| 鄂托克旗| 扶余县| 诸城市| 崇明县| 铁力市| 土默特右旗| 茌平县| 巫溪县| 阳新县| 偃师市| 浦城县| 黑龙江省| 广德县| 大庆市| 临漳县| 革吉县| 曲水县| 永福县| 阳新县| 河北区| 仲巴县| 淅川县| 静宁县| 龙岩市| 华阴市| 石台县| 合江县| 喀喇| 长岛县| 武邑县| 广州市| 敦煌市| 繁昌县| 沙湾县| 德安县| 海晏县| 福州市|